This new instrument revolutionizes the field of resistivity imaging
surveys by its capability to simultaneously measure up to 8 channels using
a high power transmitter so that field data production can reach
previously unheard of speeds.
With the high power transmitter good data can be recorded in difficult
locations where time-consuming stacking was the only alternative before.
| Measurement modes |
Apparent resistivity, resistance, induced polarization (IP),
battery voltage |
| Measurement range |
+/- 10V |
| Measuring resolution |
Max 30 nV, depends on voltage level |
| Screen resolution |
4 digits in engineering notation. |
| Output current |
1mA - 1.2A continuous |
| Output voltage |
800 Vp-p, actual electrode voltage depends on transmitted current
and ground resistivity. |
| Output power |
200W |
| Input channels |
Eight channels. |
| Input gain ranging |
Automatic, always uses full dynamic range of receiver. |
| Input impedance |
>20 MOhm |
| Input voltage |
Max 10 V |
| SP compensation |
Automatic cancellation of SP voltages during resistivity
measurement. Constant and linearly varying SP cancels completely (V/I
and IP measurements). |
| Type of IP measurement |
Time domain chargeability (M), six time slots measured and stored
in memory |
| IP current transmission |
ON+, OFF, ON-, OFF |
| IP cycle times |
1 s, 2 s, 4 s and 8 s |
| Measure cycles |
Running average of measurement displayed after each cycle.
Automatic cycle stops when reading errors fall below user set limit or
user set max cycles are done. |
| Resistivity cycle times |
Basic measure time is 1.2, 3.6, 7.2 or 14.4 s as selected by user
via keyboard. Autoranging and commutation adds about 1.4 s |
| Signal processing |
Continuous averaging after each complete cycle. Noise errors
calculated and displayed as percentage of reading. Reading displayed as
resistance (dV/I) and apparent resistivity (Ohmm or Ohmft).
Resistivity is calculated using user entered electrode distances. |
| Noise suppression |
Better than 100 dB at f>20 Hz
Better than 120 dB at power line frequencies (16 2/3, 20, 50 & 60 Hz) |
| Total accuracy |
Better than 1% of reading in most cases (lab measurements). Field
measurement accuracy depends on ground noise and resistivity.
Instrument will calculate and display running estimate of measuring
accuracy. |
| System calibration |
Calibration is done digitally by the microprocessor based on
correction values stored in memory. |
| Supported configurations |
Resistance, Schlumberger, Wenner, dipole-dipole, pole-dipole and
pole-pole. |
| Operating system |
Stored in re-programmable flash memory. Updated versions can be
downloaded from our web site and stored in the flash memory. |
| Data storage |
Full resolution reading average and error are stored along with
user entered coordinates and time of day for each measurement. Storage
is effected automatically in a job oriented file system. |
| Memory capacity |
Resistivity mode 70.000 readings, Resistivity/IP mode 25.000
readings |
| Data transmission |
RS-232C channel available to dump data from instrument to a
Windows type computer on user command. |
| Automatic multi-electrodes |
The SuperSting is designed to run dipole-dipole, pole-dipole,
pole-pole, Wenner and Schlumberger surveys including roll-along
surveys completely automatic with the Swift Dual Mode Automatic
Multi-electrode system (patent 6,404,203).
The SuperSting can run any other array by using user programmed
command files.
These files are ASCII files and can be created using a regular text
editor.
The command files are downloaded to the SuperSting RAM memory and can
at any time be recalled and run. Therefore there is no need for a
fragile computer in the field. |
| User controls |
20 key tactile, weather proof keyboard with numeric entry keys and
function keys.
On/Off switch
Measure button, integrated within main keyboard.
LCD night light switch (push to illuminate). |
| Display |
Graphics LCD display (16 lines x 30 characters) with night light. |
| Power supply, field |
12/24 V DC external power, connector on front panel.
Maximum power output is increased when using 24V supply. |
| Power supply, office |
Mains operated DC power supply. |
| Operating time |
Depends on survey conditions and size of battery used. With 24V
battery usage survey times can be reduced thanks to the higher output
power available. |
| Weight |
10.2 kg (22.5 lb), instrument only. |
| Dimensions |
Width 184 mm (7.25"), length 406 mm (16") and height 273 mm
(10.75"). |